Enable Plessy

Set this parameter to on to enable “Plessy”.

Check Digit Verification

The available options for this parameter are MOD 10 Check and Double MOD 10
Check
. This parameter uses the specified algorithm of the option you've chosen to
ensure the integrity of the symbol data before transmitting. If the data does not
contain that algorithm, the data is not transmitted.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Plessy Transmit Check Digit

If the check digit is to be transmitted with the Plessy data, this parameter must
be enabled.

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255. The length of a code
refers to the number of characters (i.e., human readable characters), including
check digit(s).

Plessy Minimum Length

Minimum lengths for the Plessy bar code can be set from 0 to 255. The length of a
code refers to the number of characters (i.e., human readable characters), including
check digit(s).

Field Size/Char

Refer to page 136 for details.

5.27.3.13 Code 11

Enabled

Set this parameter to on to enable “Code 11”.