14 code 11, Minimum and maximum length, Plessey minimum and plessey maximum length – Psion Teklogix ISO 9001 User Manual

Page 175: Field size/char, Enabled, Check digits

Advertising
background image

WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual 157

Chapter 5: Settings

Decoded (HHP)

Minimum And Maximum Length

These parameters apply to MSI bar codes. The length of a code refers to the number
of characters (i.e., human readable characters), including check digit(s). Double-
tapping on these parameters displays a screen in which you can set the minimum
and maximum allowable code lengths – 4 to 48.

Plessey Minimum And Plessey Maximum Length

These parameters apply to Plessey bar codes.The length of a code refers to the
number of characters (i.e., human readable characters), including check digit(s).
Double-tapping on these parameters displays a screen in which you can set the
minimum and maximum allowable code lengths – 4 to 48.

Field Size/Char

Refer to page 136 for details.

5.27.2.14 Code 11

Enabled

Set this parameter to on to enable “Code 11”.

Check Digits

Double-tapping on this parameter displays a dialog box in which you can choose
One Check Digit or Two check digits.
If this parameter is set to One Check Digit, it is assumed that the last digit is a
check digit. If it is set to Two Check Digits, it is assumed that the last two digits
are check digits.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable
characters), including check digit(s). Double-tapping on these parameters displays a
screen in which you can set the minimum and maximum allowable code lengths – 1
to 80.

Field Size/Char

Refer to page 136 for details.