25 micro pdf-417, 26 code 16k, 25 micro pdf-417 5.27.2.26 code 16k – Psion Teklogix ISO 9001 User Manual

Page 181: Field size/char, Enabled, Minimum and maximum length

Advertising
background image

WORKABOUT PRO Hand-Held Computer With Windows Mobile 6 Classic & Professional User Manual 163

Chapter 5: Settings

Decoded (HHP)

Field Size/Char

Refer to page 136 for details.

5.27.2.25 Micro PDF-417

Enabled

Set this parameter to on to enable “Micro PDF-417”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable
characters), including check digit(s). Double-tapping on these parameters displays a
screen in which you can set the minimum and maximum allowable code lengths – 1
to 366.

Field Size/Char

Refer to page 136 for details.

5.27.2.26 Code 16K

The “Code 16K” bar code is a multiple-row bar code that can encode the full ASCII
character set below ASCII 128. It uses existing UPC and Code 128 character set
patterns. Up to 77 full ASCII characters or 154 numeric characters can be encoded
into 2 to 16 rows. Each row is divided by a separator bar. The top and bottom of the
symbol also have separator bars that extend to the ends of the minimum quiet zones.

Enabled

Set this parameter to on to enable “Code 16K”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable
characters), including check digit(s). Double-tapping on these parameters displays a
screen in which you can set the minimum and maximum allowable code lengths – 1
to 160.

Field Size/Char

Refer to page 136 for details.

Advertising