Chapter 5 Analog Modules

Figure 5.2.8.1. illustrates a typical programming structure for the correct

operation of an SM-PT100 SMART-Module.

Figure 5.2.8.1 SM-PT100 Programming Flow Diagram

SMADCSetCyclicCalib()

(for a channel)

Sleep(0)

SMADCReadConverted()

(for a channel)

Finished

SMADCDeinit()

END

START

SMADCInit()

Install Signal Handler

- OS-Intercept

SMADCSetSensorType()

(for a channel)

SMADCEnableRead()

(for a channel)

SMADCEnableConversion()

(for a channel)

SMADCSetSignal()

(for a channel)

Yes

No