2 ctrl1 register, 3 ctrl2 register, 4 ctrl3 register – Pepper Computer Modular Computers RS485 User Manual

Page 305: 2 ctrl1 register -23, 3 ctrl2 register -23, 4 ctrl3 register -23, Smart i/o user’s manual, Chapter 6 communications modules

Advertising
background image

SMART I/O User’s Manual

©1996 PEP Modular Computers GmbH

October 01, 1996

Page 6 - 23

6

Chapter 6 Communications Modules

6.2.7.2 CTRL1 Register

ENIO-P

enable / disable (1 / 0) interrupt on parity error

ENI1-TC

enable / disable (1 / 0) interrupt on transmission complete

ENI2-EOR enable / disable (1 / 0) interrupt on end-of-range switch 1 / 2

ENI3-MH enable / disable (1 / 0) interrupt on comparison match

DIR

direction control (‘1’ activates the optocouplers)

SOT

start transmission control (‘1’ = set; single-shot-set by lib.)

AR

select automatic repeat mode (when set -> ‘1’)

RST

set / clear (1 / 0) Reset output

6.2.7.3 CTRL2 Register

FDL0-4

number of data bits, excluding parity, minus 1

P

enable / disable (1 / 0) use of parity (encoder dependent)

CF1-0

data transmission frequency:

0-0

62.5 kHz

1-0

125 kHz

0-1

250 kHz

1-1

500 kHz

6.2.7.4 CTRL3 Register

CM

A logical ‘1’ clears the MATCH output and LED

DT

data type (0:Gray, 1:Binary) according to encoder type

If ‘0’ is set, the result in the data register is binary.

PT

parity type (0:Odd, 1:Even) according to encoder type.

CTRL1-7

CTRL1-6

CTRL1-5

CTRL1-4

CTRL1-3

CTRL1-2

CTRL1-1

RST

AR

SOT

DIR

EN13-MH

EN12-EOR

ENI1-TC

CTRL2-7

CTRL2-6

CTRL2-5

CTRL2-4

CTRL2-3

CTRL2-2

CTRL2-1

CF1

CF0

P

FDL4

FDL3

FDL2

FDL1

CTRL3-7

CTRL3-6

CTRL3-5

CTRL3-4

CTRL3-3

CTRL3-2

CTRL3-1

unused

unused

unused

unused

unused

PT

DT

Advertising