8 match function, 9 tested sensors, 8 match function -26 – Pepper Computer Modular Computers RS485 User Manual

Page 308: 9 tested sensors -26, Smart i/o user’s manual, Chapter 6 communications modules

Advertising
background image

SMART I/O User’s Manual

October 01, 1996

©1996 PEP Modular Computers GmbH

Page 6- 26

Chapter 6 Communications Modules

6.2.8 MATCH Function

The match output, which is useful for detecting when an event occurs, is set

using an A > B comparator where:

A = the SSI data

B = the compare register

The MATCH output is set on an edge transition of the comparator output as

follows:

When counting up:

MATCH is set when A passes from (A<=B) to (A>B)

When counting down: MATCH is set when A passes from (A>B) to (A<=B)

6.2.9 Tested Sensors

The sensors from the following manufacturers have been tested in conjunc-

tion with the SM-SSI in an SSI environment and conform to the high stand-

ards set by PEP Modular Computers.

Hohner SSI-AVM 10-10 Multi-turn axial 24-bit Gray code

Hengstler RA58S Single-turn 12-bit Gray code

Balluff BTL 3-S11-0250-F-S50 Trans sonar distance gauge 24-bit Gray

code.