5 rs232 telephone connector (bu1), 5 rs232 telephone connector (bu1) -15, Smart i/o user’s manual – Pepper Computer Modular Computers RS485 User Manual

Page 55: Chapter 2 smart-base

Advertising
background image

SMART I/O User’s Manual

©1996 PEP Modular Computers GmbH

March 12, 1996

Page 2 - 15

2

Chapter 2 SMART-BASE

2.5.5 RS232 Telephone Connector (BU1)

In order to meet the needs of widespread standards, the RS232 connector is

selected as a telephone connector, an 8-pin RJ12 telephone jack with full

MODEM support.

* optional, for full-duplex operation

2.5.6 RS485 D-Sub Connector (BU2) for Half-Duplex Operation (Profibus)

Pin Nr.

Signal

Description

Pin Nr.

Signal

Description

1

SHIELD

Shield Isolation

6

Aux. +5V Auxiliary +5V

2

N/C

Not Connected

7

N/C

Not Connected

3

T/RxD +

Transmit / Receive Line

8

T/RxD -

Transmit / Receive Line

4

CNTR +*

Control Line

9

CNTR -*

Control Line

5

Aux. GND Auxiliary Ground

1

5

6

9

1 2

8

Pin Nr.

Signal

Description

1

DSR

Data Set Ready

2

RTS

Ready to Send

3

System GND System GND

4

TxD

Transmit Line

5

RxD

Receive Line

6

DCD

Data Carrier Detect

7

CTS

Clear to Send

8

DTR

Data Terminal Ready

Advertising