Pepper Computer Modular Computers RS485 User Manual

Page 319

Advertising
background image

SMART I/O User’s Manual

©1996 PEP Modular Computers GmbH

October 01, 1996

Page 6 - 37

6

Chapter 6 Communications Modules

FB_SSI_READ

In order that the current state of the encoder

may be read, this command is issued - nor

mally in a loop built into the ISaGRAF cycle.

The read-back value appears in the position

variable.

As can be seen from figure 6.2.11.1.1, the inputs to the module are displayed

on the left-hand side of the SSI block and the outputs are indicated on the

right-hand side.

setpoint

This is the register which contains the value of the

setpoint which is sent to the SSI module with the

Command statement.

port

The port register is used for setting the port number

of the attached SM-SSI Module.

ctrx

The control register elements; for a description of the

register please refer to the relevant section appearing

earlier.

error

If an error occurs then it’s value appears in this

variable.

position

The position of the encoder following a read is

recorded in this variable.

statusx

The status register elements; for a description of the

register please refer to the relevant section appearing

earlier.