6 configuration, 7 pinouts, 6 configuration -62 – Pepper Computer Modular Computers RS485 User Manual

Page 218: 7 pinouts -62, Smart i/o user’s manual, Chapter 5 analog modules

Advertising
background image

SMART I/O User’s Manual

March 12, 1996

©1996 PEP Modular Computers GmbH

Page 5 - 62

Chapter 5 Analog Modules

5.3.6 Configuration

Jumper J1 - EEPROM Protection

5.3.7 Pinouts

Screw Terminal Pinouts

The following shows the pinout/signal relationship for the SM-PT100 when

connected to a particular screw terminal block.

Pin 1

Pin 2

Pin 13

Pin 14

† Cold Junction point PT100 connection

Pin Nr. Signal

Description

Pin Nr. Signal

Description

1

AGND

Analog Shield

2

AGND

Analog Shield

3

In 0+

Positive Sense Line (0)

4

In 1+

Positive Sense Line (1)

5

In 0 -

Negative Sense Line (0)

6

In 1 -

Negative Sense Line (1)

7

TMP +

PT100 Cold Jn. supply

8

TMP -

PT100 Cold Jn. supply

9

In 2+

Positive Sense Line (2)

10

In 3+

Positive Sense Line (3)

11

In 2 -

Negative Sense Line (2)

12

In 3 -

Negative Sense Line (3)

13

AGND

Analog Shield

14

AGND

Analog Shield

Jumper S e t t i n g s

Description

J1

set

EEPROM is not hardware write protected

open

EEPROM is hardware write protected

Advertising
This manual is related to the following products: