4 smadc1getv, 4 smadc1getv -97, Smart i/o user’s manual – Pepper Computer Modular Computers RS485 User Manual

Page 253: Chapter 5 analog modules

Advertising
background image

SMART I/O User’s Manual

©1996 PEP Modular Computers GmbH

October 01, 1996

Page 5 - 97

5

Chapter 5 Analog Modules

5.4.8.4 SMADC1GetV

Syntax

error_code SMADC1GetV(u_int8 PortNr, u_int8 Channel,

int16 *pValue);

Description

This function fetches the conversion result of a selected channel. A gain and

offset correction is performed and the result stored as a signed integer value.

Input

u_int8 PortNr

SM-Port to be accessed

u_int8 Channel

Number of the ADC input channel to access

(0-3)

int16 *pValue

Pointer to the location where the conversion

result will be stored

Output

error_code

SUCCESS

E_SEEK

if module was not initialised

E-BMODE

if the module is unknown

or standard OS-9 error code (refer to the OS-9

Technical Manual Error Codes Section).

Example

RetVal = SMADC1GetV(0, 2, 0x07FF);

Value (16-bit HEX)

Unipolar

Bipolar

Positive Full-Scale

$0FFF

Positive Full-Scale

$07FF

+1LSB

$0001

+1LSB

$0001

0

$0000

0

$0000

-1LSB

$FFFF

Negative Full-Scale

$F800

Advertising