Polycom DOC2237A User Manual

Page 148

Advertising
background image

Chapter 5 - System Maintenance

5-4

7 LEDs on Net-E1/Net-T1 ISDN Network Interface Module, Net-4
ISDN Network Interface Module, ATM Network Interface Module and
H.323 Network Interface Module

5 LEDs on NET-2 ISDN Network Interface Module

11 LEDs on NET-8 ISDN Network Interface Module

The system uses these LEDs to indicate operating states. The LEDs on the
Net-2/Net-4/Net-8 are tri-color. Depending on the states of the LEDs inputs,
the LED can be off, green, red or yellow. The LEDs on the front panel are
described in Table 5-1.

Table 5-1: Front Panel LEDs

Module

Name

Color

Description

Main Control
Module (top
group)

CRITICAL

MAJOR

MINOR

L0

Red

Red

Yellow

Green

A critical fault is detected on the
MGC unit

A major fault exists on the MGC
unit

A minor fault exists on the MGC
unit

Reserved

Main Control
Module (bottom
group)

POWER

L1

L2

L3

Green

Green

Green

Yellow/
orange

Power Supply is operating
normally.

Only one ISDN/T1-CAS Network
card is installed in the MCU, and
it is configured as the Primary
clock source. The LED is turned
off when no ISDN Network card
is installed.

A second ISDN/T1-CAS
Network module is installed and
configured as the backup clock

LED is active when the MCU is
restarted.

Advertising