Chapter 2 - Hardware Installation

2-4

Mounting the MGC-100 on a 23” Rack

The MGC-100 can be mounted to a 23” rack using the two mounting plates
that are pre-installed on the unit.

1.

Make sure that the MCU is turned OFF and it is disconnected from the
AC or DC power.

2.

Place the MCU in a 23” rack and support it, screw the mounting brackets
to the rack securing it with bolts and
self-locking nuts (which the client provides).

-or-

If the MGC-100 was shipped without the two mounting plates that are
usually pre-installed:

1.

Make sure that the MCU power is turned OFF and that it is disconnected
from the AC or DC power.

2.

With a slotted screwdriver remove the five nylon plug hole covers from
the MCU side covers.

3.

With an Allen wrench (M4), remove the five screws from the MCU side
covers.

4.

Remove both MCU side covers.

5.

Remove the plates from the both sides of the MGC by removing the
appropriate number of functional modules to allow access to the screws.

rear

front

remove
screws