Fan replacement for the mgc-50, Fan replacement for the mgc-50 -16 – Polycom DOC2237A User Manual

Page 160

Advertising
background image

Chapter 5 - System Maintenance

5-16

Fan Replacement for the MGC-50

The fans are not hot swappable and cannot be replaced with the system
running. Fans are located on the rear pane of the MGC-50. Use the following
procedure to replace a faulty fan:

1.

Exit the MGC Manager application, turn off the MCU and unplug it from
the AC outlet.

2.

Using a standard Phillips screwdriver, remove six spring-loaded screws
from the fans cover on the MCU’s rear panel.

Lower the fans cover carefully without tearing the cables to gain access
to its inner side.

3.

Disconnect the two connectors of the power supply cable from the inside
of the fan panel. At this point, the fan panel is loose and it may be
removed.

4.

From the inside of the fan panel, push the connector panel mount locks
of the faulty fan connector and push the connector to the front of the
panel.

Advertising