Profoto ACUTE2 1200 User Manual

Page 22

Advertising
background image

22

Charging and recycling

Check that the voltage selector (7) and the frequency -

selector(8) matches the mains supply voltage. Turn on the main

switch POWER (1).

The recycling time is very short. Variations may occur depend-

ing on the selected flash energy and the mains power supply.

The shortest recycling time is obtained with low flash energy

selected with the A-, B- and A+B / A<->B-switches and the

BRACKET (15) dial.

Flash duration

The shortest flash duration is obtained by using an Acute2 twin

connected to the B sockets, the BRACKET dial set to 1/1,

the A+B/A<->B switch to the A<->B position and the B

switch set at 1/4.

Photo Cell

The built-in photo cell (11) will sense flash release as well as

IR-signals from most IR-transmitters. The photocell is turned

off with the switch SLAVE (10).

Ready lamp/test button

The ready lamp button TEST (5) has two functions. First, it

lights up when the unit is fully recycled. Second, it can be used

to manually sync the unit. When you have chosen a lower energy

setting with the dial BRACKET (15), release a flash and the

unit will recycle for the new energy setting.

Connecting Camera and Flash meter

Synchronise by connecting the sync cable from the camera or

flash meter to the sync socket (16).

(8)

(7)

(15)

(11)

(10)

(5)

(16)

Advertising