Gas generator

Most gas generators with an output of 2000W or more can

operate an Acute2 generator. Please note that you must use

a ProGas2 unit between the gas generator and the Acute2

generator to prevent damage to these two units if the gas

generator operates at 230V. For more detailed information

please see below or contact your local Profoto dealer. With

a gas generator with an output of 3000W or more 2 Acute2

generators can be operated.

A. Make sure the petrol-electric generator set produces at

least 2000W continuous output power for each connected unit.

Always check this figure against the data sheet, as the model

number does not always reflect the true power output. NOTE:

Generators less powerful than 2000W should never be used.

B. Use one 'ProGas2' (order no. 10 02 17) for each connected

Acute 2 flash unit, if a 220-240V petrol-electric generator

set is being used. The 'ProGas2' is designed to protect your

Acute2 flash unit from damaging voltage fluctuations, which

may occur when a 220-240V petrol-electric generator set

is used. The 'ProGas2' should be connected between the

220-240V petrol-electric generator set and the flash unit.

NOTE: It is not necessary to use the 'ProGas2' with a 117V

generator set.