Technical data

Guide no. In meter/feet at 100 ASA

Acute2 1200 Acute2 2400

Magnum reflector 50 degree. 128/420 180/592

Zoom reflector 64/210 90/295

Umbrella 32,5/126 45,5/180

Power requirements

• 90-130 VAC, 50 or 60 Hz. 15 Amps recommended for 2 units.

• 180-250 VAC, 50 or 60 Hz. 10 Amps recommended for 2 units.

• Gasoline generators, see guidelines on page 24

(minimum 2000W true output per flash unit). Charge speed set at Max.

Flash duration (t0.5), one head

t0,5 [1/100 s]

Acute2 1200/2400

Acute2 head

Energy [Ws] Acute2 1200 Acute2 2400 Acute2 twin

4800 n/a n/a n/a /320

2400 n/a 320 560

1200 560 560 1000

600 1000 1000 1800

300 1800 1800 3200/1800

150 3200 1800 3200/1800

75 3200 1800 3200/1800

37,5 3200 n/a 3200/ n/a