Cable connection, Pc control connector (d-sub 9p), Cable connection pc control connector (d-sub 9p) – NEC NP3151W User Manual

Page 164

Advertising
background image

50

9. Appendix

NOTE 1: Pins 1, 4, 6 and 9 are no used.

NOTE 2: Jumper “Request to Send” and “Clear to Send” together on both ends of the cable to simplify cable connection.

NOTE 3: For long cable runs it is recommended to set communication speed within projector menus to 9600 bps.

1

5

2

4

3

6 7

9

8

to gnd of PC

to rxd of PC

to txd of PC

to rts of PC

to Cts of PC

PC Control Connector (D-SUB 9P)

Cable Connection

Communication Protocol

Baud.rate........................................... .38400.bps
Data.length........................................ 8.bits
Parity................................................. No.parity
Stop.bit............................................. One.bit
X.on/off............................................. None
Communications.procedure.............. Full.duplex

NOTE: Depending on the equipment, a lower baud rate may be recommended for long cable runs.