err = flex_load_rpsps(boardID, axis, NIMC_BOTH,

50.00, 0xFF);

CheckError;

// Start the move

err = flex_start(boardID, axis, 0);

CheckError;

// End Program Storage

err = flex_end_store(boardID, 1);

CheckError;

return

;// Exit the Application

//

// Error Handling

//

nimcHandleError; //NIMCCATCHTHIS:

// Check to see if there were any Modal Errors

if

(csr & NIMC_MODAL_ERROR_MSG){

do

{

//Get the command ID, resource ID, and the

error code of the //modal error from the

error stack on the device

flex_read_error_msg_rtn

(boardID,&commandI

D,&resourceID, &errorCode);

nimcDisplayError(errorCode,commandID,res

ourceID);

//Read the communication status register

flex_read_csr_rtn

(boardID,&csr);

}while(csr & NIMC_MODAL_ERROR_MSG);

}

else

// Display regular error

nimcDisplayError(err,0,0);

return

;// Exit the Application

}