4 when using the emulator for the first time, 1 downloading firmware, 2 self-check – Renesas M3062PT-EPB User Manual

Page 26

Advertising
background image

( 24 / 80 )

2.4 When Using the Emulator for the First Time

2.4.1 Downloading Firmware

If you have purchased this emulation probe newly, you need to download the firmware. The
download procedure is given in Figure 2.3.

Before downloading the firmware, check that emulator debugger M3T-PD30F is installed to your
host machine and the PC7501 is connected to the host machine. For more details, see each user's
manual of the emulator debugger M3T-PD30F and the PC7501.

Figure 2.3 Firmware download procedure

2.4.2 Self-check

Execute the self-check after downloading the firmware to check that the emulation probe operates
properly. Figure 2.4 shows the self-check procedure.

See "3.5 Connecting the PC7501"
(page 33).

See "3.1 Selecting Clock Supply"
(page 26).

See "4.2 Downloading Firmware"
(page 48).

Figure 2.4 Self-check procedure

See "4.3 Self-check" (page 49).

Install oscillator circuit board OSC-3 (16 MHz)

included with this product to the PC7501

Connect this product and the PC7501.

Within 2 seconds of turning the power ON,

press the system reset switch of the PC7501

and check it is in maintenance mode.

Startup emulator debugger M3T-PD30F

and download the firmware.

Quit the emulator debugger

and shut down the PC7501.

Within 2 seconds of turning the power ON,

press the system reset switch of the PC7501

and check it is in maintenance mode.

After about 30 seconds, check that the self-check is

terminated normally and shut down the PC7501.

Press the system reset switch of the PC7501

to start the self-check.

Advertising