Caution – Renesas M3062PT-EPB User Manual

Page 44

Advertising
background image

( 42 / 80 )

3.6.8 Connecting to a 100-pin 0.5-mm-pitch Foot Pattern (Part 3)

Here following is a procedure of connecting to a 100-pin 0.5-mm-pitch foot pattern on the target
system using the M3T-FLX-100NSD (not included). For details on the M3T-100LCC-DMS (not
included) and M3T-FLX-100NSD, refer to each user's manual.

(1) Attach the M3T-FLX-100NSD to the target system.
(2) Attach the M3T-100LCC-DMS to the M3T-FLX-100NSD.
(3) Attach the CN2 side of the M30800T-PTC to the J4 side of the M3062PT-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.

Figure 3.19 Connecting to a 100-pin 0.5-mm-pitch foot pattern (Part 3)

CAUTION

Notes on Connecting the Target System:

• Take care not to attach a converter board in a wrong direction. It may cause a fatal

damage to the emulator and targets system.

• The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal

iterations.

• The connectors of the M3T-100LCC-DMS and M3T-FLX-100NSD are guaranteed

for only 20 insertion/removal iterations.

M3062PT-EPB

M30800T-PTC

100-pin 0.5-mm-pitch (100P6Q) foot pattern

M3T-100LCC-DMS (not included)

M3T-FLX-100NSD (not included)

YQ-GUIDE (x4)

NQPACK100SD

YQPACK100SD

These corners are not round.

*

Target board

No. 1 pin

CN2 side

M3T-FLX160-EPB

HQPACK100SD

(not included)

MCU with flash

ROM etc.

Evaluation with

actual MCU

(1)

(2)

(4)

(3)

* Available in one package