Caution – Renesas M3062PT-EPB User Manual

Page 43

Advertising
background image

( 41 / 80 )

3.6.7 Connecting to a 100-pin 0.5-mm-pitch Foot Pattern (Part 2)

Here following is a procedure of connecting to a 100-pin 0.5-mm-pitch foot pattern on the target
system using the M3T-100LCC-QSD (not included). For details on the M3T-100LCC-QSD, refer
to its user's manual.

(1) Attach the M3T-100LCC-QSD to the target system.
(2) Attach the CN2 side of the M30800T-PTC to the J4 side of the M3062PT-EPB.
(3) Attach the M30800T-PTC to the M3T-100LCC-QSD.

Figure 3.18 Connecting to a 100-pin 0.5-mm-pitch foot pattern (Part 2)

CAUTION

Notes on Connecting the Target System:

• Take care not to attach a converter board in a wrong direction. It may cause a fatal

damage to the emulator and targets system.

• The connectors of the M30800T-PTC and M3T-100LCC-QSD are guaranteed for

only 50 insertion/removal iterations.

M3062PT-EPB

100-pin 0.5-mm-pitch (100P6Q) foot pattern

M30800T-PTC

M3T-100LCC-QSD (not included)

Target board

No. 1 pin

CN2 side

M3T-FLX160-EPB

(1)

(3)

(2)

Advertising