3.6.5 Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 3)

Here following is a procedure of connecting to a 100-pin 0.65-mm-pitch foot pattern on the target system
using the M3T-FLX-100NRB (not included). For details on the M3T-100LCC-DMS (not included) and
M3T-FLX-100NRB, refer to each user's manual.

(1) Attach the M3T-FLX-100NRB to the target system.
(2) Attach the M3T-100LCC-DMS to the M3T-FLX-100NRB.
(3) Attach the CN2 side of the M30800T-PTC to the J4 side of the M3062PT-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.

Figure 3.16 Connecting to a 100-pin 0.65-mm-pitch foot pattern (Part 3)

CAUTION

Notes on Connecting the Target System:

• Take care not to attach a converter board in a wrong direction. It may cause a fatal

damage to the emulator and targets system.

• The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal

iterations.

• The connectors of the M3T-100LCC-DMS and M3T-FLX-100NRB are guaranteed

for only 20 insertion/removal iterations.

M3062PT-EPB

M30800T-PTC

100-pin 0.65-mm-pitch (100P6S) foot pattern

M3T-100LCC-DMS (not included)

M3T-FLX-100NRB (not included)

YQSOCKET100RBF

YQPACK100RB

NQPACK100RB

These corners are not round.

*

Target board

No. 1 pin

CN2 side

M3T-FLX160-EPB

HQPACK100RB

(not included)

MCU with flash

ROM etc.

Evaluation with

actual MCU

(1)

(2)

(4)

(3)

* Available in one package

The HQPACK100RB cannot be used.

Please use the HQPACK100RB168.

Advertising