6 connecting the target system, Caution – Renesas M3062PT-EPB User Manual

Page 36

Advertising
background image

( 34 / 80 )

3.6 Connecting the Target System

Figure 3.11 shows how to connect this product according to your target system.

CAUTION

Note on Connecting the Target System:

• Take care not to attach a converter board in a wrong direction. It may cause a fatal

damage to the emulator and targets system.

Figure 3.11 Connecting the target system according to target systems

Emulation probe

80-pin

0.65-mm-pitch

0.65-mm-pitch

100-pin

0.5-mm-pitch

128-pin

0.5-mm-pitch

M3062PT-80FPB

80-pin QFP

(not included)

LCC socket

100-pin LCC

(included)

M3T-DIRECT100S

100-pin QFP

(not included)

M3T-DUMMY100S

100-pin QFP

(not included)

M3T-FLX-100NRB

100-pin QFP

(not included)

M3T-F160-100NSD

100-pin LQFP

(not included)

M3T-100LCC-QSD

100-pin LQFP

(not included)

M3T-FLX-100NSD

100-pin LQFP

(not included)

M3T-F160-128NRD

128-pin LQFP

(not included)

M3T-FLX100-T

(not included)

M3T-FLX100-R

(not included)

M3T-FLX100-T

(not included)

M3T-FLX100-R

(not included)

M3T-100LCC-DMS

(not included)

M3T-100LCC-DMS

(not included)

M30800T-PTC

(included)

M30800T-PTC

(included)

*1

: No. 1 pin

*1: These three products are available in one package.