Rs-232c adjustment mode – Runco CW-50MC User Manual

Page 21

Advertising
background image

20

1) Connector: D-sub 9 pins (male)

2) Pin Layout:

Interface

Pin No.

Signal

1

NC (not connected)

2

TxD (Transmit Data)

3

RxD (Receive Data)

4

NC (not connected)

5

GnD

6

NC (not connected)

7

NC (not connected)

8

RTS (Request to Send)

9

NC (not connected)

3) Baud Rate: 9600 bps (standard)

(switchable to 1200, 2400, 4800, 19200, 38400 bps)

NOTE: The baud rate of this display should be set to match the baud rate of the computer. Also, when the

RS-232C cable is to be extended over a long distance, a slower baud rate is recommended.

4) Data Format

Start: 1-bit

Data: 8-bit

Parity: 0 (no parity)

Stop: 1-bit

5) Connection

5

9

6

1

Straight Cable

* D-sub 9-pin/D-sub 25-pin conversion tables are now available on the market

.

Control PC

Control PC

(with D25 serial port )

(with D9 serial port)

RXD 3

2 TXD

RXD 2

2 TXD

TXD 2

3 RXD

TXD 3

3 RXD

CTS 5

8 RTS

CTS 8

8 RTS

GND 7

5 GND

GND 5

5 GND

Plasma Display
(CW-43/50MC)

Plasma Display
(CW-43/50MC)

NOTE: Computer manufacturers may not use the same pin assignments. In case of communication difficulties,

check pin functions not just pin numbers.