Get commands – Runco CW-50MC User Manual

Page 29

Advertising
background image

28

GET Commands

What are GET Commands?

• They are commands for outputting TXD such as adjustment data from the internal microcomputer of the plasma

display to a PC.

• Adjustment data, etc., is output in ASCII code.

NOTE: Command names are given inside brackets < >.

• Data output format

STX (o2hex)

Data

Data

....

Checksum

ETX (03hex)

NOTE:

1) GET commands will be invalid when no ID NO. Set is assigned to the set.

2) GET commands will be invalid when wildcard (*) is used in the ID No. Set when sending the command.
1) <GST> (GET STATUS)

Order

Data Contents

Size

Remarks

1

Display data

3byte

See below

2

Power data

3byte

See below (The third character is sub input)

3

Input function data (main)

3byte

Input data when GST is received (INPUT1 to 5 is displayed as IN1 to 5)

4

Input function data (sub)

3byte

Sub input data when GST is received Note 3

(INPUT1 to 5 is displayed as IN1 to 5)

5

Screen size data

1byte

See below

6

2-screen display

1byte

0: OFF (1 screen) 1: 2-SCREEN 2: PinP (lower right)

3: PinP (upper right) 4: PinP (upper left) 5: PinP (lower left)

6: PoutP

7

FUNCTIONAL LOCK data

1byte

0: LOCK OFF 1: BUTTONS LOCK 2: IR LOCK

3: IR & BUTTONS LOCK 4: MEMORY LOCK

8

Dummy Data

3byte

(3-digit number)

9

Temperature data 2

3byte

(Internal temperature: Reference value) oC Note 1

10

Temperature data 3

3byte

(Internal temperature: Reference value) oC Note 1

11

Serial

15byte

12

Dummy data

3byte

(3-digit number)

13

Dummy data

3byte

14

HOURMETER

5byte

Display the time.

15

Checksum

2byte

Display data

First character

Generation data: 4 (fixed)

Second character Inch data: 4 (43 inches), 5 (50 inch)
Third character

Destination data: M (fixed)

Power Data

First character

Power state & signal state

Second character

PN (POWER ON & normal signal input)

PL (POWER ON & no input)

PO (POWER ON & OUT OF RANGE signal input)

SN (Normal standby)

SW (Standby by AUTO POWER OFF)

SS (Standby by SD or PD)

Third character

Sub input signal state during multi-screen display

N (Normal signal input) L (No input)

O (OUT OF RANGE signal input)

Screen size data

First character

(0) Pix by Pix or Letterbox, (1) STD (4:3), (2) ANAMPHC 16:9, (3) Letterbox

(1080i), (4) Cinema, (5) Virtualwide, (8) Letterbox (1035i), (9) Underscan

NOTE 1) During standby and immediately after POWER ON, the proper value is not output. In this case, wait a moment after POWER ON, then

get the data. The temperature data is output as a reference (the values are not guaranteed values). Normally, refer to temperature data 3.

NOTE 2) During standby and during 1-screen display, dummy data (symbol) is output.

NOTE 3) During standby and during 1-screen display the values stored in memory for the product are output.