Rs-232c adjustment mode, 6) protocol: from computer to plasmas display, Interface – Runco CW-50MC User Manual

Page 22

Advertising
background image

21

6) Protocol: From computer to plasmas display:

(1) When sending one command at a time:

STX (02 hex)

ID (2 Byte)

COMMAND (3 Byte or 6 Byte) ETX (03 hex)

COMMAND:

3 Byte (ASCII)

ARGUMENT: 3 Byte (ASCII)

(2) When transmitting commands in batches (up to max. 3 commands are possible): (NOTE)

STX (02 hex)

ID (2 Byte)

COMMAND (3 Byte)

ARGUMENT (3 Byte)

ETX (03 hex)

(3) Echo back

STX (02 hex)

COMMAND (3 Byte or 6 Byte)

ETX (03 hex)

When the recieved command is a numerical direct effect command, numerical data is returned.

STX (02 hex)

COMMAND (3 Byte)

ARGUMENT (3 Byte)

ETX (03 hex)

When the recieved command is non-corresponding command, 'ERR' is returned.

STX (02 hex)

ERR (3 Byte)

ETX (03 hex)

When it is determined that the received command cannot be processed (when PON is received when the power
is already ON, etc.) 'XXX' is returned.

STX (02 hex)

ERR (3 Byte)

ETX (03 hex)

Interface

RS-232C ADJUSTMENT MODE

Advertising