From Address 0x18 in the RAM area.

Address 0x18

Torque Enable. When power is first applied the Dynamixel enters the Torque

Free Run condition. To allow torque to be applied Address 0x18 must be set to 1.

(Torque Enabled Condition)

Address 0x19

LED is on when set to 1 and LED is off if set to 0.

Address 0x1A~0x1D Compliance Margin and Slope. The Dynamixel controls Compliance by setting the

Margin and Slope. If used well Compliance will absorb the shocks. The following

graph demonstrates the use of Compliance values (length of A,B,C & D) relative

to Position Error and applied torque.

Address 0X1E,0x1F

Goal Position. Requested Angular Position for the Dynamixel to move to. If this

is set to 0x3ff, then the goal position will be 300

°.

Goal Position

CW

CCW

CW

CCW

B

A

C D

X axis:Position Error

Y axis:Output Torque

E

A : CCW Compliance Slope(Address0x1D)
B : CCW Compliance Margin(Address0x1B)
C : CW Compliance Margin(Address0x1A)
D : CW Compliance Slope (Address0x1C)
E : Punch(Address0x30)