Dynamixel dx-116 – Robotis DX-116 User Manual

Page 9

Advertising
background image

8

English Translation by: Tribotix Pty Ltd

www.tribotix.com

DYNAMIXEL

DX-116

RS485

A multi-dropped RS485 (IEEE485) network is established from the main

controller. Data Packets are then issued through this single portal.

Please note that caution should be applied when connecting the Dynamixel units to ensure that the pin

assignments are correct. Always check the current consumption. The standby current consumption of a

Dynamixel unit should be less than 50mA.

Connection Status

When power is first applied the Dynamixel LED will blink twice to confirm its

healthy status.

Inspection

If the above operation was not successful, then check the connector pin

assignment and the voltage/current limit of the power supply.

Main

Controller

[RS485 Multi Drop Link]