Address 0x20,0x21

Moving Speed. The angular speed to move to the Goal Position. If set to the

maximum values of 0x3ff, it moves at 70RPM.

Address 0x24,0x25

Present Position. Current position of the Dynamixel.

Address 0x26,0x27

Present Speed. Current Speed of the Dynamixel.

Address 0x28,0x29

Present Load. Load size on the Dynamixel in action. Bit 10 is the direction of the

load.

Load Direction = 0 : CCW Load, Load Direction = 1: CW Load

Address 0x2A

Present Voltage. The voltage applied to the Dynamixel. The value is 10 times the

actual voltage. For example, 10V is read as 100(0x64).

Address 0x2B

Present Temperature. Current internal Dynamixel temperature (Degrees Celsius).

Address 0x2C

Registered Instruction. Set to 1 when a REG_WRITE instruction is made. After an

Action instruction and an action it is reset to 0.

Address 0x2E

Moving. Set to 1 when the Dynamixel moves by its own power.

BIT

15~11

10

9

8

7

6

5

4

3

2

1

0

Value

0

Load Direction

Load Value


(Goal Position = 0)

300°

(Goal Position = 0x3ff)

150°

(Goal Position = 0x1ff)

330~360°

Invalid Angle