Dte interface, Management, Test capabilities – RAD Data comm ASM-60 User Manual

Page 10: Real time alarms, Statistics collection

Advertising
background image

Chapter 1 Introduction

ASM-60 Installation and Operation Manual

1-2 Overview

Table 1-1. Typical ASM-60 Ranges

Data Rate

24 AWG

(Mbps) km miles

4.096 2.0

1.2

6.144

2.0

1.2

10.24

1.8

1.1

DTE Interface

The ASM-60 DTE interface supports the following interfaces:
• HSSI
• IR-ETH module with built-in Ethernet bridge
• IR-ETH/QH module with built-in Fast Ethernet bridge and VLAN support
• IR-IP module with built-in IP router.

Management

Setup, control, monitoring of status and diagnostics can be performed using an
ASCII terminal connected to the ASM-60 async DCE control port.

Test Capabilities

ASM-60 performs an extensive self-test at start-up. During the self-test, ASM-60

checks its CPU, internal framer, DTE and interfaces and power supplies. The
self-test results are displayed on the supervisory terminal.

Real Time Alarms

Real time alarms provide real time information on system status indicating loss of

synchronization on line A and line B, DCD status etc.
ASM-60 also features a log file that stores all alarms and events that occurred in the

unit. These alarms can be displayed and cleared.

Statistics Collection

ASM-60 stores the VDSL statistics for the line performance monitoring.

Advertising