Chapter 4 Management from a Terminal

ASM-60 Installation and Operation Manual

4-2

Navigating the Management Menus

Table 4-1. Control Port Control Signals

Control Line

Interface Type

DCE DTE

CTS Out Not

Used

DCD Out Out

DSR Out Out

DTR In

In

RI Not

Used

In

RTS In

In

Data Terminal Ready (DTR)
When connected and turned on, the terminal sets the DTR line ON (active) to gain

control over ASM-60 and starts a configuration or monitoring session.

Initiating a Control Session

To initiate a control session:

1. Connect the terminal cable to the CONTROL DCE connector of ASM-60.
2. Turn the control terminal on.
3. Configure the terminal to the default communication parameters: 19.2 kbps,

one start bit, eight data bits, no parity, one stop bit, VT100.

4. Select the full-duplex mode.
5. Turn the terminal echo off

You are now ready to start a control session.

4.2 Navigating the Management Menus

This section provides a general description of the software menu operation and

conventions for navigating the menus.
Figure 4-1 shows a map of the management menus in the ASM-60 embedded
software.

To choose an option:

• Type the number corresponding to the option, and press <Enter>.

The screen for the selected option is displayed.

To correct an erroneous entry:

• Press <Backspace> to clear the error, then enter the correct characters.

or
Press <Esc> to exit the current menu, and then return to the menu to

re-enter the required value.