Quick start guide, Installing asm-60, Setting the internal switches – RAD Data comm ASM-60 User Manual

Page 5: Connecting the interfaces, Connecting the power

Advertising
background image

Installing ASM-60

1

Quick Start Guide

Installation of ASM-60 should be carried out only by an experienced technician. If
you are familiar with ASM-60, use this guide to prepare the units for operation.

1. Installing

ASM-60

Setting the Internal Switches

Perform the internal settings as follows:
1. Disconnect the power cord from the power source.
2. Slide the blue side panel forward to detach it from the case.
3. Unscrew the two screws located on the bottom panel at the rear end of the

unit.

4. Separate the two halves of the ASM-60 case by lifting the top cover at the end

of the unit and sliding it forward.

5. Set the internal switches of the Ethernet interface board (IR-ETH, IR-ETH/QH

or IR-IP).

Connecting the Interfaces

1. Connect the line to the RJ-45 rear panel connector.
2. Connect the DTE to the appropriate rear panel connector.
3. Connect the control terminal to the front CONTROL DCE connector.

Connecting the Power

• Connect the AC power to the ASM-60 modem.

The PWR indicator turns on.