Roberts Gorden Tubular Unit Heaters 300 User Manual

Page 38

Advertising
background image

COMBAT

®

UHA U

NIT

H

EATER

I

NSTALLATION

O

PERATION

AND

S

ERVICE

M

ANUAL

32

14.2 Burner Compartment

14.2.1 Burner Injectors

Remove flexible

air duct from spigot

Remove

access plate

Remove screws and

pull off burner cover

Viewing port

for flame probe

Viewing port

for ignition electrode

Flame probe

Burner

compartment

cover

Rubber Seal

Ignition electrode

The burner compartment is
a sealed compartment.
Following any work,
re-seal the compartment
with the gas pipe rubber
seal fully in place and all
screws fitted and tight.

NOTE: Flexible duct only applies

for models UHAS.

MODEL

UHA[S]

150

UHA[S]

175

UHA[S]

200

UHA[S]

225

UHA[S]

250

UHA[S]

300

UHA[S]

350

UHA[S]

400

Orifice Quantity

7

8

9

10

11

12

14

14

Natural Gas (G20)

Orifice Marking

43

43

2.25 mm

2.25 mm

2.25 mm

40

40

40

P/N

91930043

91930043

91930225

91930225

91930225

91930040

91930040

91930040

Propane (G31)

Orifice Marking

1.35 mm

1.35 mm

54

54

54

1.45 mm

53

53

P/N

91930135

91930135

91930054

91930054

91930054

91930145

91930053

91930053

Ensure gas tight fitting of injectors.
Ensure correct alignment with burners.
Ensure all pipe joints are gas tight.

Advertising