Roberts Gorden Tubular Unit Heaters 300 User Manual

Page 40

Advertising
background image

COMBAT

®

UHA U

NIT

H

EATER

I

NSTALLATION

O

PERATION

AND

S

ERVICE

M

ANUAL

34

14.4 Heat Exchanger

The standard heat exchanger assembly is compossed of multiple tubular heat exchangers in models
UHA[S]150 - UHA[S]400, there is a four pass exchange.

14.5 Louvers and Louver Spring

The louvers for standard range models UHA[S]150 - UHA[S]400 are only available in horizontal
configurations.

MODEL

UHA[S]

150

UHA[S]

175

UHA[S]

200

UHA[S]

225

UHA[S]

250

UHA[S]

300

UHA[S]

350

UHA[S]

400

Aluminized Heat
Exchanger Assembly

P/N

12117100

12116100

12115100

12114100

12113100

12112100

12111100

12111100

Stainless Heat
Exchanger Assembly

P/N

12117100SS 12116100SS 12115100SS 12114100SS 12113100SS 12112100SS 12111100SS 12111100SS

Tube Heat Exchanger

Qty

7

8

9

10

11

12

14

14

Tube Plate

1

1

1

1

1

1

1

1

Tube Support

2

2

2

2

2

2

2

2

Tube Support Strap

N/A

N/A

1

1

1

1

1

1

Base Panel

1

1

1

1

1

1

1

1

End Panel Insulated

1

1

1

1

1

1

1

1

Top Panel Insulated

1

1

1

1

1

1

1

1

Rear Panel

1

1

1

1

1

1

1

1

Front Panel

1

1

1

1

1

1

1

1

Rear Fan Panel

1

1

1

1

1

1

1

1

Screws Type A/B

42

45

45

50

50

50

50

50

Push in Louver and

compress spring to

remove and replace

(opposite end first)

Horizontal
Louvers

Push in Louver and

compress spring to

remove and replace

(opposite end first)

Horizontal
Louvers

Description

UHA[S]

150 - 175

UHA[S]

200 - 250

UHA[S]

300 - 400

Horizontal Louvers P/N

11011847

11011847

11011846

Spring P/N

91901200

91901200

91901200

Quantity

7

9

11