5. READING SCALE:

Multiplication factor applied to input to get a higher or lower reading.

This is 3 byte data (6 characters) as follows:
- Bits 0 to 18 (19 bits) are value of the scale from 0 to 500000
- Bit 19 is sign, 0 for positive and 1 for negative
- Bits 20 to 23 are for decimal point value = DP

It means as:
Actual decimal value = 10 ** ( 1 - DP )
where ** means "TO THE POWER OF"

example: if scale is -0.000345678.= - 345678 x 10**(-9)

value will be 345678 decimal = 5464E hex
bit 19 =1 for negative
bits 20-23 = DP = 10 = A hex
then data will be AD464E hex

6. READING OFFSET:

Deviation applied to input to get a higher or lower reading.

This is 3 byte data (6 characters) as follows:
- Bits 0 to 19 are value from 0 to 1000000
- Bit 23 is sign, 0 for positive, 1 for negative
- Bits 20,21,22 are decimal point value = DP

It means as :
Actual decimal value = 10 ** ( 2 - DP )
where ** means "TO THE POWER OF"

example: offset value is 234.089

value of 234089 decimal = 39269 hex
decimal value = 10 ** (-3) then DP=5
then 234.089 decimal = 539269 hex

7. COMMUNICATION PARAMETERS:

This is one byte data and specifies
BAUD, PARITY, DATA, and STOP bit.
BAUD =

bits 2,1,0 are:

000-001

not used

010

for 1200

011

for 2400

100

for 4800

101

for 9600

110

for 19200

111

not used