VIII. RESET COMMANDS :

*01Z01 (For all models)

: Hard reset (reading data from EEPROM).

*01Z02 (For all models)

: Soft reset (Initialize reading).

*01Z03 (For models: TC/RTD/ACV/ACC):

Reset peak and valley.

(For models: PR/ST):

Reset process totalize value.

*01Z04 (For models: (PR/ST/FP):

Reset peak value.

*01Z05 (For models: PR/ST/FP):

Reset valley value.

*01Z07 (For models: TC/RTD/ACV/ACC):

Reset peak only.

*01Z08 (For models: TC/RTD/ACV/ACC):

Reset valley only.

NOTE:

*

: Recognition character

01

(Follow “*”)

: Address

IX.

SAMPLE PROGRAM:

' ASSUMING :

' BAUD RATE = 9600

' PARITY = ODD

' DATA BIT = 7

' STOP BIT = 1

' COMM PORT = 1

' ADDRESS = 01

' RECOG. CHAR = *

' SERIAL PORT = COM1

' FOR COMM PORT = 2 -> CHANGE "COM1:" TO "COM2:"

' THIS PROGRAM WILL GET READING AND DISPLAY IT EVERY 1 SECOND

ON ERROR GOTO ER

ON TIMER(1) GOSUB RDG

CLS

CLOSE #1

COLOR 1, 7

LOCATE 22, 30

PRINT "PRESS <ESC> TO END"

OPEN "COM1:" + "9600,O,7,1,CS,DS" FOR RANDOM AS #1

LOCATE 10, 30

PRINT "READING = "

TIMER ON

DO: LOOP UNTIL INKEY$ = CHR$(27)