DRX-RTD SPECIFICATIONS

SPECIFICATIONS:
100, 500, 1000 Ohm platinum RTD with both
European (alpha=0.00385) and American
(alpha=0.00392) curves.

Input Type:
100 Ohm

-328 to 1562 °F

-200 to 850 °C

500 Ohm

-328 to 1562 °F

-200 to 850 °C

1000 Ohm

-328 to 1562 °F

-200 to 850 °C

ISOLATION:
Dielectric strength to 1000 Vrms transient per
1 minute test based on EN 61010 for 50 Vdc or Vrms
working voltage.
Three way Isolation:

• Power to input
• Power to analog output/communication
• Input to analog output/communication

INPUT OVER-VOLTAGE PROTECTION:

250 V AC for 1 Minute

ANALOG TO DIGITAL TECHNIQUE:
Dual slope

READ RATE:
3 readings/second, automatic polarity

ACCURACY AT 25 °C:
±0.5 °C for platinum RTD’s

TEMPERATURE STABILITY:
0.05 °C/°C

STEP RESPONSE FOR RS485 OUTPUT:
2 seconds to 99% of the final value
(Filter time constant = 64)

RESPONSE TIME:
To verify the response time, check the carriage return
<CR>, it will be sent at the end of the response. You
can send another command after you receive the <CR>.
i.e.

send: *01X01
response: 01X01<DATA><CR>

Note: 01 is address.

WARM UP TO RATED ACCURACY:
30 minutes

INPUT POWER:
10 to 32 Volt DC

POWER CONSUMPTION:
2.4 Watts (100 mA at 24 V DC)

OPERATING AMBIENT:
-5 to +55 °C

STORAGE TEMPERATURE:
-40 to +85 °C

RELATIVE HUMIDITY:
90% at 40 °C non-condensing

J 2

J 2

1 2

3 4

1 2

3 4

+

-

N/C

SIGNAL INPUT

D

C

P

W

R

J 4

J2

J3

J 1

PWR

R
S
4
8
5

-TX

-RX

+TX

+RX TER

R

S

4

8

5

1 2

3

4

+EXC

+SIG

-SIG

-EXC

+EXC

+SIG

-SIG

-EXC

+EXC

+SIG

-SIG

-EXC

2 W I R E

3 W I R E

4 WIRE

R T D

R T D

R T D