119

Connecting to the Host’s RS-422A/485 Port

Section 5-2

5-2-4

1:N Connection among RS-422A Ports

The connection method in which the RS-422A ports of multiple NT631/
NT631Cs and one host are connected in a 1:N connection is described here.

Reference:

• Communications using the RS-422A standard NT link (1:N) method is

possible only when a Serial Communications Board is installed in a CS-
series PLC, a Serial Communications Unit is installed in a CS/CJ-series
PLC, a Communications Board is installed in a C200HX/HG/HE(-Z)E, or a
CQM1H-SCB41 Serial Communications Board is installed in a CQM1H.

• Communications using the RS-422A high-speed NT link (1:N) method is

possible only when a Serial Communications Board is installed in a CS-
series PLC or a Serial Communications Unit is installed in a CS/CJ-series
PLC.

NT631/NT631C

9-pin connector

CPU Unit

NT631/NT631C

NT631/NT631C

RS-422A cables
(max. total length 500 m)

CS/CJ-series PLC,
C200HX/HG/HE(-Z)E

Serial port B
(RS-422A/485, terminal block)