PTM 2-76

B070/B071

SP1902 004 (Web Near End) can be adjusted to change the near-end period. The
defaults for and amount of web that remains for copying are different for NA and
EUR/A.

Near-End

Area Near-End Web

Remaining

NA 90% 600K
EUR/A 86%

350K

The table below, provided for your reference, shows approximately how adjustment of
SP1902 002 affects the near-end and end displays on the B070 (90 cpm) or B071
(105 cpm).
Note that adjustment of SP1902 002 also affects SP1902 005 (Web Motor Control –
Web Motor Drive Interval (Low Speed)).

SP1902 002

*1

B070 B071 Low

Speed

Mode

*2

SP1902 004

*3

Near-End

Display

(Sheets)

*4

End Display

(Sheets)

Comments

20.7 s

17.0 s

25.3 s

90%

600K

670K

NA Default

15.6 s

12.8 s

19.0 s

90%

450K

500K

12.1 s

10.0 s

14.8 s

90%

350K

385K

10.4 s

8.5 s

12.7 s

90%

300K

330K

6.9 s

5.7 s

8.5 s

90%

200K

220K

12.6 s

10.4 s

15.4 s

86%

350K

410K

EUR/A Default

10.8 s

9.0 s

13.2 s

86%

300K

350K

7.2 s

6.0 s

8.8 s

86%

200K

230K

*1

: SP1902 002 (Web Motor Control – Web Motor Drive Interval)

*2

: SP1902 005 (Web Motor Control – Web Motor Drive Interval (Low Speed))

*3

: SP1902 004 (Web Motor Control – Web Near End Setting)

*4

: Calculated based on A4 LEF at 100% magnification.

NOTE: SP1902 003 (Web Motor Control – Web Near End Setting) not adjusted.