Toshiba E-STUDIO900 User Manual

Page 36

Advertising
background image

PTM 2-11

B070/B071

Original Exit (Double-Sided Original Mode)


The exit gate solenoid [A] turns on and the exit gate [B] opens.
The inverter gate solenoid [C] remains off, and the original is fed out to the upper tray.
The transport belt motor turns off when the trailing edge of the original passes the exit
sensor [D].
To stack the originals neatly on the upper tray, the feed-out motor speed is reduced
shortly after the trailing edge of the original turns off the inverter sensor [E].

B070D929.WMF

[A]

[C]

[E]

[D]

[B]