B070/B071

2.12.3 LOW POWER MODE

Entering the low power mode

The machine enters low power mode when:
The energy saver timer runs out after the last job.
(User Tools - System Settings - Timer Setting - Energy Saver Timer: default setting is
15 min)

What happens in low power mode

The fusing lamp drops to the prescribed temperature, as shown in the table below (the
temperature drops more than that in energy saver mode). The other conditions are the
same as for the energy saver mode.

Return to stand-by mode

The machine returns to standby mode in the same way as from the energy saver
mode.

Operation

Switch

Energy Saver

LED

Fusing Temp.

Approx.

Recovery Time

System +5V

On On

143

°C (B070/90 cpm)

150

°

C (B071/105 cpm)

40 s