2.1 DOCUMENT FEEDER

2.1.1 PICK-UP ROLLER RELEASE



When the original set sensor is off (no original on the original tray), the pick-up roller
stays in the up position.
When the original set sensor turns on (or when the trailing edge of a page passes the
entrance sensor while pages remain on the original tray), the pick-up motor [A] turns
on. The cam [B] rotates away from the pick-up roller release lever [C]. The lever then
rises and the pick-up roller [D] drops onto the original.
When the original reaches the entrance sensor, the pick-up motor turns on again. The
cam pushes the lever down, and the pick-up roller rises until the pick-up roller HP
sensor [E] detects the actuator [F].

B070D916.WMF

[A]

[D]

[C]

[E]

[B]

[F]