Setting Switcher Output Timing

With the Effects Send option installed in a Model 3000, the PGM
output on Aux Buses 1 through 4 was delayed compared to other
switcher outputs. Software provides an adjustment of the
switcher length that allows you to match the timing of all outputs.

CAUTION

Adjustment of the switcher output timing is not recommended
unless you have the Effects Send option and you expect to use
PGM out on Aux Buses 1 through 4.
Increasing the switcher length may affect other timing in your
facility.

The switcher length timing adjustment is done in the
Configuration/Outputs/Output Timing menu.

1.

To gain access to the switcher length adjustment, first press
the

CONFG

button on the main menu subpanel, then press the

OUTPUTS>

soft button in the Configuration menu.

OUTPUTS MENU

ON

ON

config / outputs

CHROMA CLIP

= 105 %

LUM CLIP
= 105 IRE

ON

COMPOSITE CLIP

= 138 IRE

ON

PGM

M/E 1 PGM
M/E 2 PGM

AUX BUS 1
AUX BUS 2
AUX BUS 3
AUX BUS 4
AUX BUS 5
AUX BUS 6
AUX BUS 7

FRAMESTORE

ON
ON

OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF

-
-
-
-
-
-
-
-
-
-

-
-

ON

OFF
OFF
OFF

-
-
-
-

BLACK CLIP

= -20 IRE

ON

OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF

OFF

OFF

OFF

OFF

PGM

OFF

ON

ON

OFF

SUPER
BLACK

OUTPUT

SELECT

SETUP

ON KEY

UNSHAPER

LIMITER

OUTPUT

TIMING >

DIGITAL

RES >