Configuring gpi outputs, Gpi outputs menu – Tektronix Grass Valley 3000 User Manual

Page 88

Advertising
background image

2-52

Section 2 — Startup & Configuration

Configuring GPI Outputs

GPI Output triggers each time there is a cut on the PGM Bus. This
GPI is typically connected to an external device such as a clock/
timer which is reset by each trigger. Such a clock would then
indicate how long the current source has been on air.

The duration of GPI Output Triggers can now be configured by
the number of fields. This configuration is set using the GPI
Outputs Menu.

Use the GPI Outputs Menu to set E-MEM levels for each assigned
GPI. You may also set the duration of the GPI trigger signal. This
menu is accessed from the Config/External If Menu.

1.

Use the

SELECT GPI

button to select the desired GPI number.

2.

Press the

E-MEM LEVEL

button to select the desired E-MEM

level.

3.

Use the

LENGTH

soft knob to select the required GPI trigger

duration in fields.

4.

Repeat Steps 1 through 3 for other GPIs.

GPI OUTPUTS MENU

GPI 7

GPI 6

GPI 5

GPI 4

GPI 3

GPI 2

GPI 1

OFF

config / external if / gpi outputs

PGM CUT
TRIGGER

E-MEM

LEVEL

LENGTH

= 1 Field