Cl18 cl7, Ldap 800 thermostat wiring, Field wiring – Thomas & Betts LDAP 1200 User Manual

Page 15: Cl2 cl1 cl3, Cl18, Cl18 cl7 cl7, W2 r w1 g, W2 r w1 g w2, W1 r g, W2 w1 r g

Advertising
background image

Form RZ-NA-I-LDAP, P/N 207733 (Rev 2), Page 15

W

(OPT CL1) W

.R. 1C30-341 THERMOST

A

T

R

R

(OPT CL2) W

.R. 1C30-341

W

-S23-6 SUBBASE

W

G

Y2

R

W1

G

Q674G SUBBASE

(OPT CL7) T874F THERMOST

A

T

W2

R

W1

Q674C SUBBASE

(OPT CL18) T874F THERMOST

A

T

RH

W2

RC

W1

G

W2

W1

R

G

(OPT CL3) T874F THERMOST

A

T OR

Y1

C

W2

Y2

Y1

C

SINGLE STAGE HEATING

TWO STAGE HEATING

TERMINAL STRIP

(SEE NOTE #5)

(OPT CL7) T874F THERMOST

A

T

R

W2

Q674C SUBBASE (SEE NOTES #4 & #5)

(OPT CL18) T874F THERMOST

A

T

W1

RH

RC

G

W2

W1

Y1

Y2

C

W2

R

W1

G

TERMINAL STRIP

TERMINAL STRIP

SINGLE STAGE HEATING

WITH RECIRCULATION

LDAP 400 THERMOSTAT WIRING

FIELD WIRING

WD# 189504 REV. #2

LDAP 400 - Thermostat Option CL1,

CL2, CL3, CL7 or CL18

NOTES:

1) Set the anticipator at 0.6 amps.

2) Set thermostat first stage anticipator at

0.6 amps and second stage anticipator at

0.2 amps.

3) Jumper thermostat terminals RH to RC.

4) Jumper thermostat terminals RH to RC

and G to W1.

5) Set thermostat first stage anticipator at

maximum amps and second stage

anticipator at 0.6 amps.

CL2

CL1

CL3

(SEE NOTE #1)

(SEE NOTE #1)

CL18

CL18

CL7

CL7

(

SEE NOTES #4 & #5)

Q674G SUBBASE

(SEE

NOTE

#2

AND

#3)

(SEE NOTE #2)

W2

R

W1

G

W

(OPT CL1) W

.R. 1C30-341 THERMOST

A

T

R

R

(OPT CL2) W

.R. 1C30-341

W

-S23-6 SUBBASE

W

G

W2

R

W1

G

W2

Q674G SUBBASE

(OPT CL7) T874F THERMOST

A

T

W2

R

W1

W1

R

G

Q674C SUBBASE

(OPT CL18) T874F THERMOST

A

T

RH

W2

RC

W1

G

W2

W1

R

G

(OPT CL3) T874F THERMOST

A

T OR

TERMINAL STRIP

UNIT #1

Y1

Y2

C

Y1

Y2

C

TERMINAL STRIP

UNIT #1

Y1

Y2

C

Y1

Y2

C

UNIT #2

TERMINAL STRIP

TERMINAL STRIP UNIT #2

PR

PR

R

R

PR

R

PR

R

TERMINAL STRIP

Q674G SUBBASE

(OPT CL7) T874F THERMOST

A

T

R

W2

Q674C SUBBASE

(OPT CL18) T874F THERMOST

A

T

W1

RH

RC

G

W2

W1

Y1

Y2

C

W2

R

W1

G

SINGLE STAGE HEATING

TWO STAGE HEATING

R

PR

C

R

W2

G

W1

R

PR

TERMINAL STRIP UNIT #2

Y2

Y1

WITH RECIRCULATION

SINGLE STAGE HEATING

UNIT #1

LDAP 800 THERMOSTAT WIRING

FIELD WIRING

WD# 189505 REV. #2

LDAP 800 - Thermostat Option CL1,

CL2, CL3, CL7 or CL18

NOTES:

1) Set the anticipator at 0.6 amps.

2) Set thermostat first stage anticipator

at 0.6 amps and second stage anticipator

at 0.2 amps.

3) Jumper thermostat terminals RH to RC.

4) Jumper thermostat terminals RH to RC

and G to W1.

5) Set thermostat first stage anticipator at

maximum amps and second stage

anticipator at 0.6 amps.

(SEE NOTE #1)

CL2

CL1

CL3

(SEE NOTE #5)

CL18

CL7

(SEE NOTES #4 & #5)

CL18

CL7

(SEE

NOTE

#2

AND

#3)

(SEE NOTE #2)

(SEE NOTE #1)

FIGURE 11 - Thermostat
Connections for Model
LDAP 800 with Option
CL1, CL2, CL3, CL7, or
CL18

FIGURE 10 - Thermostat
Connections for Model
LDAP 400 with Option CL1,
CL2, CL3, CL7, or CL18

Advertising