Wiring diagrams (cont’d), 1 dsi control – Thomas & Betts LDAP 1200 User Manual

Page 24

Advertising
background image

Form RZ-NA-I-LDAP, P/N 207733 (Rev 2), Page 24

23. Wiring Diagrams (cont’d)

FIGURE 15 – Typical Wiring Diagram for Model LDAP 800 (Reference W.D. 189375, Rev 2)

208 OR 230/1/60

VENTER MOTOR

& CAPACITOR

BK

L1

#1 VENT PERMISSIVE

RELAY CONTACTS

2

4

A

BK

Y L3

MAIN

PR

L1

A

BK

PR

RELAY CONTACTS

#2 VENT PERMISSIVE

2

4

PR

BK

PR

BK

GRD

G

N

BK

Y

BL

BR

Y

7

BR

BK

BL

8

8

L1

L1

7

L3

L3

BK

DISCONNECT

(SEE NOTES on page 22.)

T1

L1

L3

T2

L3

T3

CUSTOMER'S FUSIBLE

LOCKABLE ON/OFF

DISCONNECT

BK

Y

BK

BL

LINE VOLTAGE

(See NOTE 7 on page 22.)

COM

40 VA. CONTROL

TRANSFORMER

BR

Y

BK

BL

COM

40 VA. CONTROL

TRANSFORMER

BR

Y

MOTOR

TEST

GROUND

ELECTRODE

FLAME

BL

GAS VALVE

FLAME

BR

R

BR

BL

P1-9

P1-7

P1-4

P1-2

SPARK GAP

#1 DSI

CONTROL

LED

G

OK

TRANSFORMER

NEUTRAL

FLAME

Y

SPARK

W

J

4uF CAPACITOR

REMOTE MOUNTED

W

BR/W

W

BR

BK

G

BK

R

O

W2

R

W1

R

Y

8

BL

BK

L1

G

PR

BL

RELAY CONTACTS

#1 HEAT PERMISSIVE

CONTROL

LIMIT

PRESSURE

Y

Y

SWITCH

R

2

R

HIGH LIMIT

MANUAL

CONTROL

RESET

Y

4

Y

R

R

P1-6

P1-5

P1-3

P1-8

R

P3-5

P3-4

P3-2

P3-3

P3-1

8

8

BL

BL

ADJUSTABLE

FAN CONTROL

DESTRAT

MAIN COMBUSTION AIR

SWITCH

PRESSURE

C

BL

NO

R

G

SCREW

GRD

PERMISSIVE

RELAY CONTACTS

#1 FAN

COM

FUSE

C

R

W

G

A

TO OR

A

TC

3.0

AMP

SWITCH SETTINGS

SEC

Y

L1

BL

10

R

R

SW1

BR

L1

NEUTRAL

EAC/BLO

M1

NEUTRAL

BK

BK

IND

Y

W

R

4

Y

NEUTRAL

O

10

O

9

R

O

9

O

F

BL

PR

PR

20uF CAPACITOR

3

VENTER

Y

BK

BK

1

W

BR/W

2

BK

C

2

BK

5

FAN

MOTOR

BL

2

H

W

3

GR

G

BL

RELAY CONTACTS

G

N

#1 DESTRAT

GRD

G

R

3

BR

1

BK

1

Y

BR

7

7

3

O

BR

BR

1

R

3

BR

3

1

O

BR

BR

BR

1

7

7

7

7

L3

Y

BK

REMOTE MOUNTED

L1

BK

R

L1

BK

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

39

40

36

37

38

46

45

44

42

43

41

20
CR

21

CR

22

CR

23

CR

RELAY COIL

#2 HEAT

PERMISSIVE

RELAY COIL

62

#1 HEAT

PERMISSIVE

38

RELAY COIL

#2 DESTRAT

RELAY COIL

#1 DESTRAT

54

30

PR

RELAY CONTACTS

2

PR

BL

4

#1 REMOTE DESTRAT

BL

#1 VENT

PERMISSIVE

13

RELAY COIL

CR

42

Y1

Y2

C

29

RELAY COIL

#1 REMOTE

DESTRAT

W

1

1

CR

3

3

45

BR

7

BR

TERMINAL STRIP

UNIT #1

30 - 31

#1 FAN

PERMISSIVE

RELAY COIL

CR

36

G

G

B

BL

Y

BR

7

BR

L3

Y

8

L1

BL

BL

BK

Y

47

51

50

49

48

7

BK

SEE NOTE 6 ON P

AGE 22.

SEE CHART PAGE 23 FOR

LINE VOLTAGE

(See NOTE 7 on page 22.)

The above control wiring is

repeated in the second heat section.

SWITCH

LED