10. Heater

Location

Use the clearances in Paragraph 8; the combustion air requirements in Paragraph 9;
the mounting height requirements, throw information, sound data, and location rec-
ommendations below; the weights in Paragraph 11; and the venting requirements in
Paragraph 24 to determine where to suspend the heater.

Mounting Height

Locate the heater so that it is a minimum of 15 feet (4.6M) above the floor and in
compliance with the clearances in Paragraph 8.

WARNING: If touched, the vent pipe and internal heater surfaces
that are accessible from outside the heater will cause burns. Suspend
the heater a minimum of 15 feet (4.6M) above the floor.

CAUTION: Do not locate the heater where it may be exposed to
water spray, rain, or dripping water.

Heater Throw -
All Models

NOTES:

X = Distance from “0” to beginning
of floor coverage.

Y = Distance from “0” to end of
floor coverage.

Length of floor coverage = Y - X.

Z = Distance from “0” to the point
where the air velocity drops below
50 feet (15.2M) per minute.

Throws listed are with standard
louvers facing one direction and
fully open. Throw pattern changes
with louver angle, 2-way louver
direction, and or optional 4-way
louvers.

Throw (feet and meters)

FIGURE 3 - Model LDAP Air Throw (Heat Mode @ High Speed) - Applies to All Sizes

0 = “Rear” of Heater Discharge

Mounting

Height

Standard Louvers

30° Nozzle

60° Nozzle

X
Y
Z

X
Y
Z

X
Y
Z

Standard
Louvers

30° Nozzle

60° Nozzle

0

X

Y

Z

X

Y

Z

X

Y

Z

20

5

55

134

40

90

146

70

125

158

30

8

53

121

44

86

133

76

119

145

40

12

49

109

47

81

120

N/A

N/A

N/A

50

17

45

96

N/A

N/A

N/A

N/A

N/A

N/A

X

Y

Z

X

Y

Z

X

Y

Z

6.1

1.5

16.8

40.8

12.2

27.4

44.5

21.3

38.1

48.2

9.1

2.4

16.2

36.9

13.4

26.2

40.5

23.2

36.3

44.2

12.2

3.7

14.9

33.2

14.3

24.7

36.6

N/A

N/A

N/A

15.2

5.2

13.7

29.3

N/A

N/A

N/A

N/A

N/A

N/A

M

o

unti

n

g

Hei

g

ht

(Meters

)

Standard Louvers

30° Degree Nozzle

60° Degree Nozzle

Throw (meters)

M

o

unti

n

g

Hei

g

ht

(feet)

Standard Louvers

30° Degree Nozzle

60° Degree Nozzle

Throw (feet)

Advertising