Fan

Motor

Heat Section Pressure Switch

Venter Motor Capacitor

Fan Motor Capacitor

High Limit Control

and Adjustable Destrat

Fan Control

Disconnect Switch

Transformer

Gas Valve

DSI Control (Circuit Board)

Fan Permissive Relay

Ignitor

Heat Permissive Relay

(Models 800 and 1200)

Flame Sensor

Terminal Boards

Limit Control

Vent Permissive Relay

(Models 800 and 1200)

Remote Destrat Relay

Destrat Relay

24V Thermostat

Terminal Board

Burner Assembly

Venter Motor

FIGURE 22 - Location of Controls

30. Burner

Maintenance

Each section of this heater is equipped with a

T

CORE

2

®

burner (U.S. Patent No.

6,889,686). Size 400 has one; Size 800 has two; and Size 1200 has three.

Inspect each burner/control compartment annually to determine if cleaning is neces-
sary. If there is an accumulation of dirt, dust, and/or lint, clean the compartment and
follow the instructions below to remove and clean the burner.

1. Outside the cabinet, shut the gas supply off at the manual valve ahead of the

union.

2. Turn off electric supply.
3. Disconnect the gas supply at the union outside of the cabinet.
4. Remove the access panel.
5. Disconnect the Gas Train and Move It Out of the Way - At the gas valve,

mark and disconnect the wires. Disconnect the union on one or both sides of the
gas line inside of the heater. Carefully remove the burner orifice and orifice
adapter locking nut. Slide the orifice adapter out through the bracket on the
burner.

Burner Removal
Instructions
(Refer to
FIGURE 23.)

29. Heat

Exchanger
Maintenance

Each section of this heater is equipped with a

T

CORE

2

®

heat exchanger (U.S.

Patent No. 6,889,686). Size 400 has one; Size 800 has two; and Size 1200 has three.

Remove any external dirt or dust accumulation. Visually check each heat exchanger
for cracks and holes. If a crack or hole is observed, replace the heat exchanger.

NOTE: Inspection of the lower portion of the heat exchanger is done with the burner
removed. See the Burner Service section below for information on inspecting the
lower portion of the heat exchanger.

CAUTION: Use of eye

protection is

recommended.

Check the wiring for any damaged wire. Replace damaged wiring. (See

Paragraph 14 for replacement wiring requirements.)