FIREPLACE SPECIFICATIONS

Vent Size

Co-axial DV Vent Size

4-1/2" Inner

7-1/2" Outer

Notes

* The Steady State Effi ciency numbers based on
maximum vent confi guration.

Due to Lennox' ongoing commitment to quality,
all specifi cations, ratings and dimensions are
subject to change without notice.

Effi ciencies

Natural Gas

Propane

Models

EnerGuide

Steady

State

AFUE

EnerGuide

Steady

State

AFUE

SSDV-3530

55

67

63

60

68

64

SSDV-4035

60

69

65

61

69

65

Input (BTU) - MV & Electronic

Natural (NG) & Propane (LP) Gas

Models

Fuel

Input Rate (BTU / HR)

SSDV-3530

NG

High 23,000

Low 17,500

LP

High 23,000

Low 17,500

SSDV-4035

NG

High 29,000

Low 21,500

LP

High 29,000

Low 22,500

Vertical Venting Through the Ceiling:
Frame ceiling opening
- Use a plumb line from the ceiling above the appliance to locate center of the vertical run. Cut and/or
frame an opening, 10

¹⁄₂" x 10¹⁄₂" (267 mm x 267 mm) inside dimensions, about this center mark (see Figure 19).

G

F**

H

16

(406)

1/2 (13)

3 (76)

Top View

*Co-axial Direct Vent Pipe

Flue - 4-1/2 (114)

Combustion Air - 7-1/2 (190)

Framing Spacers

(Top, Sides & Rear)

GAS INLET

(Either Side

and bottom)

*

SSDVR models are
rear vent only
SSDVT models are
top vent only

(Louvered Front Model Shown)

**Rear vent models only

Electrical Inlet

2-3/4 x 2 (70 x 51)
Cover Plate
W/Knockout

Right Side View

9

(229)

E

B

D

C

Front View

3 (76)

A

1-3/8

(35)

(Optional)
ELECTRICAL
INLET Knockout
Requiring A Field
Provided Junction
Box (Either Side)

(140)

5-1/2

9-3/8
(238)

2

(53)

NOTE - Hood shown as

positioned in louvered

front model.

Fireplace Dimensions - Inches (millimeters)

Model A

B

C

D

E

F

(rear vent only)

G

H

SSDVT-3530
SSDVR-3530

35-1/8 (892)

32-1/8 (816)

19 (483)

29-1/2 (749)

35-1/8 (892)

21-11/16 (551)

24-7/8 (632)

12-7/16 (316)

SSDVT-4035
SSDVR-4035

40-1/8 (1019)

37-1/8 (943)

24 (610)

34-1/2 (876)

40-1/8 (1019)

26-11/16 (678)

29-7/8 (759)

14-15/16 (379)

Framing Dimensions - Inches (millimeters)

Models

A

B

C

D

E

SSDVT-3530

35-1/4 (895)

35-1/4 (895)

N/A

39-3/4 (1010)

16"

SSDVR-3530

35-1/4 (895)

35-1/4 (895)

21-11/16 (551)

N/A

16"

SSDVT-4035

40-1/4 (1022)

40-1/4 (1022)

N/A

44-3/4 (1137)

16"

SSDVR-4035

40-1/4 (1022)

40-1/4 (1022)

26-11/16 (678)

N/A

16"

A

B

D

7

(178)

5-1/8

12-1/8

12-1/8

(308)

10-1/2

(

267

)

C

VENT FRAMING -
TOP VENT WITH ONE
90

• ELBOW

VENT FRAMING -
REAR VENT WITH
NO ELBOWS

**Framing should be constructed

of 2 x 4 or larger lumber.

Inches (millimeters)

E

(130)

5-1/8

1/2

(130)

7

(308)

(178)

E is the required framing depth dimension when the

finish material (drywall) thickness is 1/2 in. (13mm).

A

**Framing With Square Horizontal Termination SV4.5HT-2

Figure 14