NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

20

SV4.5 HT-2

Termination

SV4.5 HT-2

Termination

Horizontal terminations have been designed to perform in a wide range of weather condi-
tions. Our terminations meet or exceed industry standards.

When selecting the locations of your horizontal terminations, do not place the termina-
tion where water from eaves and adjoining roofl ines may create a heavy fl ow of cascad-
ing water onto the termination cap. If the cap must be placed where the possibility of
cascading water exists, it is the responsibility of the builder to direct the water away
from the termination cap by using gutters or other means.

Take care to carefully follow the installation instructions for the termination, including
the use of silicone caulking where required.

Figure 33

Figure 32 -

INSTALLING SQUARE HORIZONTAL TERMINATION (SV4.5HT-2)

Siding

Stucco

1-1/4” Maximum Recess of
Square Termination
into Exterior Finishing Material

Exterior Surface of
Framing

Exterior Surface of Siding

Maximum Extent of
Vent Run Sections
Relative to Exterior
Surface of Framing

Interior Surface of
Finished Wall

Last Vent Section.

Use Telescopic Vent

Section (SV4.5LA), If

Necessary

Adapter

SV4.5RCH

Use silicone caulking to seal

the top and sides of the
termination, up to the
underlayment, stucco, or
masonry wall surface.

Caulk

Caulk

Maximum Wall Thickness
10 in. (254 mm)

6 in. to 9-1/4 in.
(152 to 235 mm)

10

¹⁄₂"

(267mm)

7"

(178)

5

¹⁄₈"

(130 mm)

12

¹⁄₈"

(308 mm)

Note: Centerline of Vent Piping is

NOT the Same as the Centerline of

the Framed Opening.

6 to 48 inch Vent Section,

Telescopic vent section,

Elbow or Appliance Collar

Base of Appliance

3"

(76 mm)

1"

(25.4 mm)

Adapter

SV4.5RCH

To help minimize water infiltration it is
recommended that the Firestop/Spacer

(SV4.5HF) be installed on the exterior

side of the wall.

Venting Connection and Exterior Wall Recessing of the Horizontal Square
Termination (SV4.5HT-2).

See Figure 14 on Page 11 for Min.
Distance to Base of Appliance.

For thicknesses greater

than 10", see Table 12

SV4.5 HT-2

Termination

J. Assemble vent run to exterior wall - If not
previously measured, locate the center of the
vent at the exterior wall. Prepare an opening as
described in Step B. Assemble the vent system
to point where the terminus of the last section is
located relative to the exterior surface to which
the termination is to be attached (see Figures
32 & 33 and Table 12 on Page 21
.

If the terminus of the last section is not within
this distance, use the telescopic vent section
SV4.5LA,
as the last vent section. For wall thick-
nesses greater than that shown in Figure 33 on
Page 20 and
Table 12 on Page 21. This table
lists the additional venting components needed
(in addition to the termination and adapter) for
a particular range of wall thicknesses.

K. Attach termination adapter - Attach the
adapter (adapter - SV4.5RCH - provided with the
termination) to the vent section or telescoping
vent section, elbow or appliance collar as shown
in Figures 32 & 33 in the same manner as any
SV4.5 vent component (refer to Step E).

L. Install Firestop/Spacer at exterior wall
-
When using the square termination, install
SV4.5HF (Secure Vent), SF4.5HF (Secure Flex)
Firestop/Spacer over the opening at the exterior
side of the framing, long side up, with the 3 inch
spacer clearance at the top as shown in Figure
32
, and nail into place.

(The Firestop/Spacer may also be installed over
the opening at the interior side of framing).

M. Install the Square Termination (SV4.5HT-2)

Install the square termination - For the last step
, from outside the exterior wall, slide the collars
of the termination onto the adapter (the outer
inside the outer and the inner outside the inner)
until the termination seats against the exterior
wall surface to which it will be attached. Orient
the housing of the termination with the arrow
pointed upwards. Secure the termination to
the exterior wall. The horizontal termination
must not be recessed into the exterior wall
or siding
by more than the 1-1/4" (32 mm) as
shown in Figure 33.

IMPORTANT

The vent termination is hot while
in operation and for a period of
time following the use of the fi re-
place. To prevent contact with hot
surfaces, we recommend the use
of a Termination Guard
. See Items
12 and 13
on Page 33. This can be
purchased at your local dealer.

Advertising